Brand |
---|
Mercury 2kVA (2000VA) Automatic Voltage Regulator (AVR) A2000D – 2KVA Mercury Stabiliser, Relay Type
SKU:
AVR-2000VA
Categories: Mercury, Stabilizers
Additional information
Reviews (0)
Be the first to review “Mercury 2kVA (2000VA) Automatic Voltage Regulator (AVR) A2000D – 2KVA Mercury Stabiliser, Relay Type” Cancel reply
Shipping & Delivery
Related products
Mercury Elite220I, 220AH/12V Tall Tubular Battery
Mercury SP6240U-4U, 1.8M, UK. SURGE PROTECTOR
Specification
Input Nominal Voltage 230VAC Current 10A (Max) Phase Single phase Indication Power Indicator Neon Type Cable Length 1.8m / 5m Input Plug British Type / Schuko Type Output Socket 6 x Universal Output DC (Total) 4 USB 5V2A • Surge protection • Fire proof design • EMI/RFI protection • Thunder protection • Overload protection • Safe and reliable design Environment Temperature -20˚C~90˚C Storage Temperature -35˚C~95˚C Humidity 0%~95%RH (Non-condensing) 200~230VAC Electrical Appliances Power Consumption Chart Hair Dryer 1000W Iron 750W Fax Machine 55W Inkjet Printer 52W PC 180W~300W 17” CRT Monitor 80W LCD TV 40W~60W DVD Player 25W Video Cassette Player 40W Mixer 100W~150W Refrigerator 800W~1200W 6240U-4UMercury Maverick 850VA UPS
Input voltage 220VAC
Input frequency 50Hz
Input phase Single phase
Input socket With Fuse
Cold Start (0 to 100% load) Press the ON/OFF switch
Input range (220V) 140V-300V
Rating output (VA). 850VA
Rating output (W). 510W
Rating output (W). Battery mode(simulated sine wave),
AC mode (sine wave)
Power factor 0.6
Rating voltage 220V
Output range 220Vac-7%+15% ( in battary mode )
Rear Output Socket 2xUniversal - Battery backup
Transfer time TYPICAL 4-8 ms
Communication Interface NIL
Rating frequency 50Hz
Output Frequency Line-mode Synchronize with the Utility
Battery mode 50 Hz±1Hz
Output Frequency Line Mode Synchronize with the utility
Short Circuit Protection Line Mode FUSE & firmware protection
Battery Mode Software protection controlled by firmware
Overload Protection Line Mode 110%+-5% (Go to fault mode after 5 minutes),
120%+-5% (Go to fault mode immediately)
Battery Mode 110%+-5% (Shutdown after 5 minutes)
120%+-5% (Shut down immediately)
Rating frequency 12V/9AH x 1
Backup Tim - Typical 10mins to 18mins
(depending on load)
Charge Current About 1A at normal mode
Over Charge Protection >14.5V +/- 0.2V stop charging
Weight 5.6kg +/- 0.3Kg
Dimension 390x 145 x 220 (mm)
Mercury Elite220I, 220AH/12V Tall Tubular Battery
Mercury Maverick 1550VA UPS
Specification:
Model: – Capacity: 1550VA/930W Input : – Voltage 220-230VAC – Voltage Range 140-300 VAC – Frequency: 50 / 60Hz – Current:7.2A Max Output: – Voltage Regulation (Bat.Mode): +/-10% – Frequency :50 / 60Hz – Waveform: Simulated Sine wave Battery: – Battery Type: 12V / 8.2AH x2 – Charging ability: 6 hours recover to 90% capacity Transfer Time: – Typical:2-6ms Protection: Short circuit, Overload, Battery discharge and overcharge, Surge Protection Indications: – Line Mode: Greenlighting – Battery Mode : Yellow flashing – Fault: Red Lighting Audible Alarm: – Battery Mode: Sounding every 10 sec – Battery low: Sounding every 1 sec – Overload: Sounding every 0.5 sec – Fault: Continuous sounding Environment: – Humidity 0-90% relative Humidity 0-40°C (Non-condensing) – Noise Level : Less than 40dB – Dimension: 313 x129 x175Mercury Elite 2000VA UPS
Rating input voltage | 2000 VA / 1200 W |
Rating input frequency | 60/50Hz (auto sensing) |
Input phase | Single-phase |
Input socket | With Fuse |
Cold Start (0 to 100% load) | Press the ON/OFF Switch |
Input Range (220V) | 140-300 |
Rating output(VA) | 2000 |
Rating output (W) | 1200 |
Power factor | 0.6 |
Rating output voltage (V) | 220 |
Waveform | Battery mode (simulated sine wave), AC mode(sine wave) |
AC Voltage Regulation | ±10% (Battery mode) |
Rear output socket | 4 x Universal – Battery backup |
Waveform | Simulated Sine Wave (Battery mode) |
Line Mode | Synchronize with the utility |
Rating frequency | 60Hz or 50 Hz ± 1 Hz |
Battery Mode | Yellow flashing |
Short circuit protection Line Mode | Fuse & Firmware protection |
Short circuit protection Battery Mode | Firmware Protection |
Overload protection Line Mode | 110%±5%; Go to fault mode Line Mode after 5 minutes, 120%±5%; Go to fault mode immediately. |
Overload protection Battery Mode | 110%±5%; Shutdown after 5 seconds, 120%±5%, Shutdown immediately |
Indicators AC mode | Green Lighting |
Indicators Battery Mode | Yellow Flashing |
Indicators Fault | Red Lighting |
Alarm Battery Mode | Sounding every 10 Seconds |
Alarm Low Battery | Sounding every Second |
Alarm Overload | Sounding every 0.5 second |
Alarm Fault | Continuously sounding |
Full Protection | Overload, discharge, and Overcharge protection |
Transfer Time | Typical 2-6ms, 10ms max. |
Transfer Time | Typical 2-6ms, 10ms max. |
Communication Interface | Optional RS232/RJ11 |
Battery and runtime Rating | 2 X 12V/9AH |
Recharge time – Typical | 6-8 hours recover to 90% capacity |
Charge current | About 1A at normal mode. |
Dimension, W X H X D (cm) | 22.5 X 12.5 X 39 |
Net Weight (kgs) | 12.7KGS |
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 45dB |
Compatible with OS | Supports Windows® 2000/2003/XP/Vista/2008/7 |
Communication interface | Elite 2000pro (N/A), Elite 2000ipro (USB/RJ11) |
Reviews