Specifications
Power 6KVA / 4200W
Voltage range 176 ±5VAC~276 ±5VAC
Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing
Input phase Single-phase
Power factor ≥0.98
Voltage range 220VAC ±1%
Output phase Single phase
se
Frequency 50Hz ±0.2% (battery mode)
THD < 2% (Linear load); < 6% (non-Linear load)
Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass mode
Crest factor 3:1 (max)
Waveform Pure sine wave
Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)
Efficiency ≥88%
AC mode 5 cycles turn off the inverter, no transfer to Bypass,
provide alarm.
Battery mode 5 cycles turn off the inverter, provide an alarm.
Bypass mode Input fuse has blown or break action.
Battery Model 12V sealed lead acid maintenance-free
DC voltage 240VDC
Configuration 20x 12V/8.2AH
Backup time 20min (half load) / 7min (full load)
Charge current 1A (standard unit) / 5A (long time unit)
Recharge time 90% capacity after 8hrs charging
Communication Interface RS232; SNMP (optional)
Parallel Port Parallel availability for redundancy and load sharing up to three-units
LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass”
LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operation
Noise level ≤ 55dB
Temperature 0~40˚C; 0 ~ 40˚C (storage temperature)
Humidity 0~95% (non-condensing)
Altitude < 1500m
Weight Net/Gross 89/104kg (standard unit); 34/48kg (long time unit)
Dimension (WxDxH) 270 x 570 x 720mm
Packaging (WxDxH) 370 x 670 x 940mm
Mercury Envy 6KVA Online UPS.
Description
Mercury 6kva Online UPS Single Phase MP9106S
Application: Small network, servers and other IT
equipment
High frequency and double conversion on-line technology
Fully digitized microprocessor control
Wide input voltage range
UPS startup without battery
Cold start
Advanced battery management
Advanced battery charge in UPS off mode
Lightning and surge protection
Short circuit and surge protection
Fan speed auto control when loads vary Optional extension battery pack
Load capacity display
Smart RS232 communication with monitoring software
Optional SNMP card slot
SKU:
ENVYRT6KVA
Categories: ENVY SERIES RACKMOUNT ONLINE UPS, Mercury
Description
Additional information
Brand |
---|
Reviews (0)
Be the first to review “Mercury Envy 6KVA Online UPS.” Cancel reply
Shipping & Delivery
Related products
Mercury HP9110C-S 10KVA Online UPS
₦1,097.77
Specifications
Power | 10KVA / 7000W |
Voltage range | 176 ±5VAC~276 ±5VAC, |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing |
Input phase | Single-phase |
Power factor | ≥0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single-phase |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) |
Efficiency | ≥88% |
AC mode | 5 cycles turn off the inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off the inverter, provide an alarm. |
Bypass mode | Input fuse has blown or break action. |
Battery Model | 12V sealed lead acid maintenance-free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 13min (half load) / 5min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three-units |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ≤ 55dB |
Temperature | 0~40˚C; 0 ~ 40˚C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 92/107kg (standard unit); 36/51kg (long time unit) |
Dimension (WxDxH) | 270 x 570 x 720mm |
Packaging (WxDxH) | 370 x 670 x 940mm |
Mercury 120V MI7500 Sine Wave Inverter.
Mercury 7500VA/120V Inverter, MH-7500 - 7.5kVA Pure Sine Wave Inverter with Digital Display
Pure Sine Wave Inverter for Clean, stable Output
Suitable for all loads: inductive (air conditioners, refrigerator), motors (vacuum cleaners) & rectifier load (computer).
Cold Start
Fully digitised microprocessor controlled LED
Built-in Charger
Selectable charging current 20A & 40A
Intelligent long backup model
Super efficient DC-AC Conversion
Wide input range [90V -275V inverter mode 115V -270V UPS mode]
Energy saving function with UPS green mode
Critical overload protection
Automatic Switchover to Inverter Mode
Short circuit and overload protection
Battery Protection
600W output capacity
Compatible with generator
Mercury Elite 2000VA UPS
₦54,000.00
Mercury Elite 2000VA Pro Ups
Mercury Elite 2000VA Pro Line Interactive UPS provides a vigorous backup solution for your home and office power backup needs. The Mercury Elite 2000VA Pro UPS (2KVA) gives solid protection for your equipment. It comes with a built-in AVR function to protect against dangerous NEPA fluctuations.Features
The Mercury Elite 2000VA Pro UPS is designed with advanced technology to deliver maximum availability and durability. * Wide input voltage range * Compatible with generators * Overload protection * Short circuit protection * Built-in AVR * Battery deep discharge protection & overcharge protection 1-year warranty, backed with local service support at its well-equipped service centers, Mercury UPS will deliver long years of dependable service.ficationMercury Elite 2000VA UPS
Rating input voltage | 2000 VA / 1200 W |
Rating input frequency | 60/50Hz (auto sensing) |
Input phase | Single-phase |
Input socket | With Fuse |
Cold Start (0 to 100% load) | Press the ON/OFF Switch |
Input Range (220V) | 140-300 |
Rating output(VA) | 2000 |
Rating output (W) | 1200 |
Power factor | 0.6 |
Rating output voltage (V) | 220 |
Waveform | Battery mode (simulated sine wave), AC mode(sine wave) |
AC Voltage Regulation | ±10% (Battery mode) |
Rear output socket | 4 x Universal – Battery backup |
Waveform | Simulated Sine Wave (Battery mode) |
Line Mode | Synchronize with the utility |
Rating frequency | 60Hz or 50 Hz ± 1 Hz |
Battery Mode | Yellow flashing |
Short circuit protection Line Mode | Fuse & Firmware protection |
Short circuit protection Battery Mode | Firmware Protection |
Overload protection Line Mode | 110%±5%; Go to fault mode Line Mode after 5 minutes, 120%±5%; Go to fault mode immediately. |
Overload protection Battery Mode | 110%±5%; Shutdown after 5 seconds, 120%±5%, Shutdown immediately |
Indicators AC mode | Green Lighting |
Indicators Battery Mode | Yellow Flashing |
Indicators Fault | Red Lighting |
Alarm Battery Mode | Sounding every 10 Seconds |
Alarm Low Battery | Sounding every Second |
Alarm Overload | Sounding every 0.5 second |
Alarm Fault | Continuously sounding |
Full Protection | Overload, discharge, and Overcharge protection |
Transfer Time | Typical 2-6ms, 10ms max. |
Transfer Time | Typical 2-6ms, 10ms max. |
Communication Interface | Optional RS232/RJ11 |
Battery and runtime Rating | 2 X 12V/9AH |
Recharge time – Typical | 6-8 hours recover to 90% capacity |
Charge current | About 1A at normal mode. |
Dimension, W X H X D (cm) | 22.5 X 12.5 X 39 |
Net Weight (kgs) | 12.7KGS |
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 45dB |
Compatible with OS | Supports Windows® 2000/2003/XP/Vista/2008/7 |
Communication interface | Elite 2000pro (N/A), Elite 2000ipro (USB/RJ11) |
Mercury Elite 2000VA UPS
Rating input voltage | 2000 VA / 1200 W |
Rating input frequency | 60/50Hz (auto sensing) |
Input phase | Single-phase |
Input socket | With Fuse |
Cold Start (0 to 100% load) | Press the ON/OFF Switch |
Input Range (220V) | 140-300 |
Rating output(VA) | 2000 |
Rating output (W) | 1200 |
Power factor | 0.6 |
Rating output voltage (V) | 220 |
Waveform | Battery mode (simulated sine wave), AC mode(sine wave) |
AC Voltage Regulation | ±10% (Battery mode) |
Rear output socket | 4 x Universal – Battery backup |
Waveform | Simulated Sine Wave (Battery mode) |
Line Mode | Synchronize with the utility |
Rating frequency | 60Hz or 50 Hz ± 1 Hz |
Battery Mode | Yellow flashing |
Short circuit protection Line Mode | Fuse & Firmware protection |
Short circuit protection Battery Mode | Firmware Protection |
Overload protection Line Mode | 110%±5%; Go to fault mode Line Mode after 5 minutes, 120%±5%; Go to fault mode immediately. |
Overload protection Battery Mode | 110%±5%; Shutdown after 5 seconds, 120%±5%, Shutdown immediately |
Indicators AC mode | Green Lighting |
Indicators Battery Mode | Yellow Flashing |
Indicators Fault | Red Lighting |
Alarm Battery Mode | Sounding every 10 Seconds |
Alarm Low Battery | Sounding every Second |
Alarm Overload | Sounding every 0.5 second |
Alarm Fault | Continuously sounding |
Full Protection | Overload, discharge, and Overcharge protection |
Transfer Time | Typical 2-6ms, 10ms max. |
Transfer Time | Typical 2-6ms, 10ms max. |
Communication Interface | Optional RS232/RJ11 |
Battery and runtime Rating | 2 X 12V/9AH |
Recharge time – Typical | 6-8 hours recover to 90% capacity |
Charge current | About 1A at normal mode. |
Dimension, W X H X D (cm) | 22.5 X 12.5 X 39 |
Net Weight (kgs) | 12.7KGS |
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 45dB |
Compatible with OS | Supports Windows® 2000/2003/XP/Vista/2008/7 |
Communication interface | Elite 2000pro (N/A), Elite 2000ipro (USB/RJ11) |
Reviews