Rating input voltage | 2000 VA / 1200 W |
Rating input frequency | 60/50Hz (auto sensing) |
Input phase | Single-phase |
Input socket | With Fuse |
Cold Start (0 to 100% load) | Press the ON/OFF Switch |
Input Range (220V) | 140-300 |
Rating output(VA) | 2000 |
Rating output (W) | 1200 |
Power factor | 0.6 |
Rating output voltage (V) | 220 |
Waveform | Battery mode (simulated sine wave), AC mode(sine wave) |
AC Voltage Regulation | ±10% (Battery mode) |
Rear output socket | 4 x Universal – Battery backup |
Waveform | Simulated Sine Wave (Battery mode) |
Line Mode | Synchronize with the utility |
Rating frequency | 60Hz or 50 Hz ± 1 Hz |
Battery Mode | Yellow flashing |
Short circuit protection Line Mode | Fuse & Firmware protection |
Short circuit protection Battery Mode | Firmware Protection |
Overload protection Line Mode | 110%±5%; Go to fault mode Line Mode after 5 minutes, 120%±5%; Go to fault mode immediately. |
Overload protection Battery Mode | 110%±5%; Shutdown after 5 seconds, 120%±5%, Shutdown immediately |
Indicators AC mode | Green Lighting |
Indicators Battery Mode | Yellow Flashing |
Indicators Fault | Red Lighting |
Alarm Battery Mode | Sounding every 10 Seconds |
Alarm Low Battery | Sounding every Second |
Alarm Overload | Sounding every 0.5 second |
Alarm Fault | Continuously sounding |
Full Protection | Overload, discharge, and Overcharge protection |
Transfer Time | Typical 2-6ms, 10ms max. |
Transfer Time | Typical 2-6ms, 10ms max. |
Communication Interface | Optional RS232/RJ11 |
Battery and runtime Rating | 2 X 12V/9AH |
Recharge time – Typical | 6-8 hours recover to 90% capacity |
Charge current | About 1A at normal mode. |
Dimension, W X H X D (cm) | 22.5 X 12.5 X 39 |
Net Weight (kgs) | 12.7KGS |
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 45dB |
Compatible with OS | Supports Windows® 2000/2003/XP/Vista/2008/7 |
Communication interface | Elite 2000pro (N/A), Elite 2000ipro (USB/RJ11) |
Mercury Maverick 1550VA UPS
Specification:
Model: – Capacity: 1550VA/930W Input : – Voltage 220-230VAC – Voltage Range 140-300 VAC – Frequency: 50 / 60Hz – Current:7.2A Max Output: – Voltage Regulation (Bat.Mode): +/-10% – Frequency :50 / 60Hz – Waveform: Simulated Sine wave Battery: – Battery Type: 12V / 8.2AH x2 – Charging ability: 6 hours recover to 90% capacity Transfer Time: – Typical:2-6ms Protection: Short circuit, Overload, Battery discharge and overcharge, Surge Protection Indications: – Line Mode: Greenlighting – Battery Mode : Yellow flashing – Fault: Red Lighting Audible Alarm: – Battery Mode: Sounding every 10 sec – Battery low: Sounding every 1 sec – Overload: Sounding every 0.5 sec – Fault: Continuous sounding Environment: – Humidity 0-90% relative Humidity 0-40°C (Non-condensing) – Noise Level : Less than 40dB – Dimension: 313 x129 x175Mercury HP9110C-S 10KVA Online UPS
₦1,097.77
Specifications
Power | 10KVA / 7000W |
Voltage range | 176 ±5VAC~276 ±5VAC, |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing |
Input phase | Single-phase |
Power factor | ≥0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single-phase |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) |
Efficiency | ≥88% |
AC mode | 5 cycles turn off the inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off the inverter, provide an alarm. |
Bypass mode | Input fuse has blown or break action. |
Battery Model | 12V sealed lead acid maintenance-free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 13min (half load) / 5min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three-units |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ≤ 55dB |
Temperature | 0~40˚C; 0 ~ 40˚C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 92/107kg (standard unit); 36/51kg (long time unit) |
Dimension (WxDxH) | 270 x 570 x 720mm |
Packaging (WxDxH) | 370 x 670 x 940mm |
Mercury Maverick 850VA UPS
Input voltage 220VAC
Input frequency 50Hz
Input phase Single phase
Input socket With Fuse
Cold Start (0 to 100% load) Press the ON/OFF switch
Input range (220V) 140V-300V
Rating output (VA). 850VA
Rating output (W). 510W
Rating output (W). Battery mode(simulated sine wave),
AC mode (sine wave)
Power factor 0.6
Rating voltage 220V
Output range 220Vac-7%+15% ( in battary mode )
Rear Output Socket 2xUniversal - Battery backup
Transfer time TYPICAL 4-8 ms
Communication Interface NIL
Rating frequency 50Hz
Output Frequency Line-mode Synchronize with the Utility
Battery mode 50 Hz±1Hz
Output Frequency Line Mode Synchronize with the utility
Short Circuit Protection Line Mode FUSE & firmware protection
Battery Mode Software protection controlled by firmware
Overload Protection Line Mode 110%+-5% (Go to fault mode after 5 minutes),
120%+-5% (Go to fault mode immediately)
Battery Mode 110%+-5% (Shutdown after 5 minutes)
120%+-5% (Shut down immediately)
Rating frequency 12V/9AH x 1
Backup Tim - Typical 10mins to 18mins
(depending on load)
Charge Current About 1A at normal mode
Over Charge Protection >14.5V +/- 0.2V stop charging
Weight 5.6kg +/- 0.3Kg
Dimension 390x 145 x 220 (mm)